50 Hz: 770 - 1290 kVA
60 HZ : 615 – 1180 KW 

MTU 2000 DS - G05

Proven reliability from 615 to 1180 kWe (60Hz) and 770 to 1290 kVA (50 Hz). MTU 2000 DS generator sets with Series 2000G05 engines offer the ideal solution for a wide range of applications.

  • Series MTU 2000 DS

    With the comprehensive choice of power outputs from 770 to 1290 kVA MTU 2000 DS generator sets offer the optimum solution for various applications.

    Cutting-edge emissions control Superior on-site specific derating behavior due to state-of-theart engine controller with engine site condition management system Verified product design, quality and performance integrity Robust fuel injection technology for maximum reliability Compliant with industry codes & standards: The generator set fulfills performance per ISO 8528 and offers 100% load acceptance according to NFPA 110 Permanent magnet excitation system for generator as standard for improved transient response Best-in-class reliability and availability Optimized maintenance intervals > Contact

    Industry leading load factor

    85% load factor for standby applications and 75% load factor for prime power applications

    ISO Designed and manufactured

    Our facilities are certified to standards ISO 9001:2008 and ISO 14001:2004

    Advanced monitoring & communications

    Wide range of applications available from island operation to mains parallel operation

    Product list for MTU 2000 DS - G05

    Product

     

    Standby Applications

     

    Prime Applications

       
    Standby Power
     
    Prime Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

     

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    MTU 12V2000 DS850 - G05

     

    850 kVA

     

    770 kVA

    MTU 12V2000 DS890 (TB*) - G05

     

    890 kVA

     

    820 kVA

    MTU 16V2000 DS1000 - G05

     

    1000 kVA

     

    900 kVA

    MTU 16V2000 DS1050 (TB*) - G05

     

    1050 kVA

     

    910 kVA

    MTU 16V2000 DS1100 - G05

     

    1100 kVA

     

    1000 kVA

    MTU 16V2000 DS1140 (TB*) - G05

     

    1140 kVA

     

    1030 kVA

    MTU 18V2000 DS1250 - G05

     

    1250 kVA

     

    1130 kVA

    MTU 18V2000 DS1290 (TB*) - G05

     

    1270 kVA

     

    1160 kVA

    Product

     

    Standby Applications

       
    Standby Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

    MTU 12V2000 DS850 - G05

     

    850 kVA

    MTU 12V2000 DS890 (TB*) - G05

     

    890 kVA

    MTU 16V2000 DS1000 - G05

     

    1000 kVA

    MTU 16V2000 DS1050 (TB*) - G05

     

    1050 kVA

    MTU 16V2000 DS1100 - G05

     

    1100 kVA

    MTU 16V2000 DS1140 (TB*) - G05

     

    1140 kVA

    MTU 18V2000 DS1250 - G05

     

    1250 kVA

    MTU 18V2000 DS1290 (TB*) - G05

     

    1270 kVA

    Product

     

    Prime Applications

       
    Prime Power
       

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    MTU 12V2000 DS850 - G05

     

    770 kVA

    MTU 12V2000 DS890 (TB*) - G05

     

    820 kVA

    MTU 16V2000 DS1000 - G05

     

    900 kVA

    MTU 16V2000 DS1050 (TB*) - G05

     

    910 kVA

    MTU 16V2000 DS1100 - G05

     

    1000 kVA

    MTU 16V2000 DS1140 (TB*) - G05

     

    1030 kVA

    MTU 18V2000 DS1250 - G05

     

    1130 kVA

    MTU 18V2000 DS1290 (TB*) - G05

     

    1160 kVA

    Product

     

    Standby Applications

     

    Prime Applications

       
    Standby Power
     
    Prime Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

     

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    North and Latin America

    MTU 12V2000 DS750 (TB*)

     

    750 kWe

     

    680 kWe

    MTU 12V2000 DS800 (TB*)

     

    800 kWe

     

    725 kWe

    Product

     

    Standby Applications

       
    Standby Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

    North and Latin America

    MTU 12V2000 DS750 (TB*)

     

    750 kWe

    MTU 12V2000 DS800 (TB*)

     

    800 kWe

    Product

     

    Prime Applications

       
    Prime Power
       

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    North and Latin America

    MTU 12V2000 DS750 (TB*)

     

    680 kWe

    MTU 12V2000 DS800 (TB*)

     

    725 kWe

    *TB: Water-to-air charge air cooling

    Options for MTU 2000 DS - G05

    Cooling System

    integral set-mounted mechanical radiators for up to 50°C ambient temperatures

    Fuel System

    fuel pre-filters with water separators

    Exhaust system

    silencers from varying sound attenuation levels

    Starting/ Charging System

    Batteries; redundant starter, air starter, battery charger

    > CONTACT

    Register for our Newsletter

    Subscribe to our MTU eReport and stay up to date with news and stories around our brands MTU Onsite Energy and MTU.

    > Subscribe here