50 Hz: 750 - 1400 kVA
60 Hz: 1000 - 1250 kWe

MTU 2000 DS - G06

With the comprehensive choice of power outputs from 1000 to 1250 kWe (60 Hz) and 750 to 1400 kVA (50 Hz) the new MTU 2000 DS generator sets with Series 2000G06 engines offer the optimum solution for various applications. The State-of-the-art common rail technology sets benchmarks in respect of the efficiency.

  • Series MTU 2000 DS

    With the comprehensive choice of power outputs from 615 to 1250 kWe (750 to 1400 kVA) MTU 2000 DS generator sets offer the optimum solution for various applications.

    Verified product design, quality, and performance integrity and cutting-edge emissions control Superior on-site specific derating behavior due to state-of-the-art engine controller with engine site condition management system State-of-the-art common rail injection system for superior efficiency Compliant with industry codes & standards The generator set fulfills performance per ISO 8528 and offers 100% load acceptance according to NFPA 110. Permanent magnet excitation system for generator as standard for improved transient response. Best-in-class reliability and availability Optimized maintenance intervals Options to fulfil worldwide certifications: ISO 8528, CE/IEC, UL2200, NFPA 110, IBC2009 (for 60Hz), German Grid Code (for 50Hz) > Contact

    Industry leading load factor

    85% load factor for standby applications and 75% load factor for prime power applications

    ISO Designed and manufactured

    Our facilities are certified to standards ISO 9001:2008 and ISO 14001:2004

    Advanced monitoring & communications

    Wide range of applications available from island operation to mains parallel operation

    Product list for MTU 2000 DS - G06

    Product

     

    Standby Applications

     

    Prime Applications

     

    Continuous Applications

       
    Standby Power
    Standby Power with Overload
    Data Center Continuous Power
    Mission Critical Power
     
    Prime Power
    Grid Stability Power
     
    Continuous Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

    Load factor is <85% for up to 500 h of operating hours per year. With 10% overload capability for one hour in 12.

    Used in data centers as emergency standby units for the duration of an emergency outage. Load factor is <100% for unlimited operating hours per year. With 10% overload capability for one hour in 12.

    Power output available with varying load for the duration of an emergency outage. Average load factor ≤ 85% for up to 1000 h of operating hours per year. 50Hz: A 10% overload capacity is available for one hour in 12. 60Hz: No overload capability.

     

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    Used to stabilize grid when renewable power sources are used or in grid programs like STOR. Load factor is <100% for up to 1000 h of operating hours per year. With 10% overload capability for one hour in 12.

     

    At constant load, the number of operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Load factor is ≤ 100%.

    Europe, Africa, Asia and Australia

    MTU 12V2000 DS825

     

    825 kVA

    750 kVA

    --

    --

     

    750 kVA

    --

     

    --

    MTU 12V2000 DS1000

     

    1010 kVA

    800 kVA

    --

    --

     

    800 kVA

    --

     

    750 kVA

    MTU 16V2000 DS1000

     

    --

    910 kVA

    --

    --

     

    910 kVA

    --

     

    --

    MTU 16V2000 DS1100

     

    1100 kVA

    1000 kVA

    1000 kVA

    1000 kVA

     

    1000 kVA

    1000 kVA

     

    --

    MTU 16V2000 DS1250

     

    1250 kVA

    1135 kVA

    --

    --

     

    1135 kVA

    --

     

    800 kVA

    MTU 18V2000 DS1400

     

    1400 kVA

    1250 kVA

    1250 kVA

    1250 kVA

     

    1250 kVA

    1250 kVA

     

    1000 kVA

    North and Latin America

    MTU 18V2000 DS1400

     

    1400 kVA

    --

    --

    --

     

    1250 kVA

    --

     

    --

    Product

     

    Standby Applications

       
    Standby Power
    Standby Power with Overload
    Data Center Continuous Power
    Mission Critical Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

    Load factor is <85% for up to 500 h of operating hours per year. With 10% overload capability for one hour in 12.

    Used in data centers as emergency standby units for the duration of an emergency outage. Load factor is <100% for unlimited operating hours per year. With 10% overload capability for one hour in 12.

    Power output available with varying load for the duration of an emergency outage. Average load factor ≤ 85% for up to 1000 h of operating hours per year. 50Hz: A 10% overload capacity is available for one hour in 12. 60Hz: No overload capability.

    Europe, Africa, Asia and Australia

    MTU 12V2000 DS825

     

    825 kVA

    750 kVA

    --

    --

    MTU 12V2000 DS1000

     

    1010 kVA

    800 kVA

    --

    --

    MTU 16V2000 DS1000

     

    --

    910 kVA

    --

    --

    MTU 16V2000 DS1100

     

    1100 kVA

    1000 kVA

    1000 kVA

    1000 kVA

    MTU 16V2000 DS1250

     

    1250 kVA

    1135 kVA

    --

    --

    MTU 18V2000 DS1400

     

    1400 kVA

    1250 kVA

    1250 kVA

    1250 kVA

    North and Latin America

    MTU 18V2000 DS1400

     

    1400 kVA

    --

    --

    --

    Product

     

    Prime Applications

     

    Continuous Applications

       
    Prime Power
    Grid Stability Power
     
    Continuous Power
       

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    Used to stabilize grid when renewable power sources are used or in grid programs like STOR. Load factor is <100% for up to 1000 h of operating hours per year. With 10% overload capability for one hour in 12.

     

    At constant load, the number of operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Load factor is ≤ 100%.

    Europe, Africa, Asia and Australia

    MTU 12V2000 DS825

     

    750 kVA

    --

     

    --

    MTU 12V2000 DS1000

     

    800 kVA

    --

     

    750 kVA

    MTU 16V2000 DS1000

     

    910 kVA

    --

     

    --

    MTU 16V2000 DS1100

     

    1000 kVA

    1000 kVA

     

    --

    MTU 16V2000 DS1250

     

    1135 kVA

    --

     

    800 kVA

    MTU 18V2000 DS1400

     

    1250 kVA

    1250 kVA

     

    1000 kVA

    North and Latin America

    MTU 18V2000 DS1400

     

    1250 kVA

    --

     

    --

    Product

     

    Standby Applications

     

    Prime Applications

       
    Standby Power
     
    Prime Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

     

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    North and Latin America

    MTU 18V2000 DS1250

     

    1250 kWe

     

    1000 kWe

    Product

     

    Standby Applications

       
    Standby Power
       

    Power output available with varying load for the duration of an emergency outage. Average load factor is <85% for up to 500 h of operating hours per year. No overload capability.

    North and Latin America

    MTU 18V2000 DS1250

     

    1250 kWe

    Product

     

    Prime Applications

       
    Prime Power
       

    Power output available with varying load for unlimited time when grid is not available. Load factor is <75%. With 10% overload capability for one hour in 12.

    North and Latin America

    MTU 18V2000 DS1250

     

    1000 kWe

    *TB: Water-to-air charge air cooling

    Options for MTU 2000 DS - G06

    Cooling System

    Integral set-mounted mechanical radiators for up to 50°C ambient temperatures; Jacket water heater

    Fuel System

    Fuel pre-filters with water separators; fuel return cooler

    Exhaust system

    Silencers for varying sound attenuation levels

    Starting/ Charging System

    Batteries; redundant starter, air starter, battery charger

    Switch Gear

    Base frame mounted or stand alone circuit breakers